v 6.1.8: Public release (2022-05-19):
  - PIPE-9969 ingest modified static calibration files into Archive (updated hdr keywords)
  - PIPE-9871 tweak appearance of global param on workflow canvas
  - Upgrade to latest HDRL version

v 6.1.7: Paranal release (2022-03-15):
  - PIPE-9896 ensure products use RADESYS instead of RADECSYS, and do not contain HDRVER
  - PIPE-9871 add a globalparameter to regulate the RecipeLooper behaviour in all workflow
  - PIPE-9825 fix illegal \verb command usage
  - PIPE-9659 reflect new support channel in documentation
  - PIPE-9545 proper use of user-provided params in subsequent recipe executions from interactive Reflex windows
  - PIPE-9534 fix various bugs in the uves-fibre workflow
  - PIPE-9476 fix mismatch of minlines=$INIT_MAXLINES in the CreateInitialSoP actor of Wavelength Calibration
  - Reflect new FTP server in documentation
  - Fix several broken links/URLs in documentation

v 6.1.6: Public release (2021-06-01):
  - PIPE-9525 Correct tooltips for reduce.extract.method for uves_obs_scired/uves_cal_response
  - PIPE-9479 Why offer a parameter if changing it causes the recipe to fail?
  - PIPE-9326 Description reduce.rebin.wavestep_redu and reduce.rebin.wavestep_redu parameters
  - PIPE-9324 Documentation of reduce.slitlength and reduce.objoffset in Reflex tutorial
  - PIPE-9302 Wrong information in SpectrumExtraction interactive window
  - PIPE-9235 Bug in UVES WKF wavelength calibration interactive GUI python script
  - PIPE-9226 QC.LINE.RESIDAVG is always zero
  - PIPE-9215 2D extraction with uves_obs_scired produces 1-D FLUXCAL_2D_SCIENCE product
  - PIPE-9137 Reflex worflow fails on slicer data
  - PIPE-9113 pipeline manual: replace response_hdrl_chip.fits w response_fine_chip.fits
  - PIPE-9033 Update of pipeline and reflex manuals for public releaase 2020
  - PIPE-8926 Verify UVES pipeline manual and reflex tutorial
  - PIPE-8723 Reflex: objoffset in interactive window, but not objslit
  - PIPE-8714 Reference to A&A Reflex paper and documentation link missing from canvas
  - PIPE-8249 uves_obs_scired: --reduce.rebin.scale = true gives bad quality spectra
  - PIPE-7645 Change time window for association of INSTR_RESPONSE_<arm> in Reflex OCA rules
  - PIPE-2116 Document in the manual a rare numerical instability and provide a workaround

v 6.1.4:
  - PIPE-9094 FLAMES-UVES reflex data reduction seg fault on MacOS HighSierra 10.13.6 (with clang)

v 6.1.3: Proposed Public release (2020-06-03):
  - PIPE-9077 scale response curve tables before plotting (makes vert axis tick labels legible)
  - PIPE-9065 Adjust OCA rules for MASTER_RESPONSE and remove FAQ for 860 data
  - PIPE-9059 minimum set of mandatory keywords present in new/changed static calibs
  - PIPE-9039 use HDRL to generate response curves, don't save smoothed response curve to disk
  - PIPE-9036 split static calibrations for X-shooter/other standard stars
  - PIPE-9029 UVES static calibration RESP_FITS_POINT_CATALOG
  - PIPE-9020 Update OCA rules and workflow xml file
  - PIPE-8983 Update online man page for uves_cal_response/uves_obs_science
  - PIPE-8951 PRO keywords mssing for INSTR_RESPONSE_FINE_<chip>
  - PIPE-8931 Update reflex tutorial
  - PIPE-8925 Clean up telluric correction
  - PIPE-8924 Remove obsolete static calibrations
  - PIPE-8923 Update UVES pipeline manual
  - PIPE-8922 Update documentation and static files for UVES pipeline (public release)

v 6.1.1: Proposed Paranal release (2020-03-18):
  - PIPE-8969: (missing) PRO keywords mssing for INSTR_RESPONSE_FINE_<chip>

v 6.1.0: Proposed Paranal release (2020-03-11):
  - Fix PIPE-8969 uves_obs_scired does not apply extinction correction

v 6.0.0: Paranal release (2020-03-04):

v 5.10.19 (2020-01-28):
  - Merged branch  PIPE-8398 (Improvement response computation and flux caliration)
  This fixes the following actions: response computation and flux caliration (part of PIPE-8398)
    PIPE-8829 Extinction correction is not applied for efficiency calculation
    PIPE-8815 strange line shape in observed spectrum used to determine response for 346 setup
    PIPE-8813 Static calibrations not proeperly handled
    PIPE-8810 reference line positions for RV correction of flux standard stars
    PIPE-8809 BUNIT keyword is wrong for flux-calibrated spectra
    PIPE-8808 RESP_FIT_POINTS_CATALOG should use the X-shooter fit points for the X-shooter standard stars
    PIPE-8803 Verify noise propagation if reduce.ffmethod=pixel and reduce.extract.method=2d
    PIPE-8801 FLUX_STD_CATALOG: mismatch between extension name and star name
    PIPE-8773 Implement telluric correction for UVES flux standard stars
    PIPE-8759 Self-calibrated flux standard star spectra do not agree with reference data
    PIPE-8717 Add EG21 to the new flux standard star catalog
    PIPE-8716 uves_cal_response does not find standard stars
    PIPE-8660 wrong default value for flames_cal_prep_sff_ofpos method in the flames-uves workflow
    PIPE-8656 Flux calibrated spectrum is 0
    PIPE-8601 Port your pipeline python scripts to python3
    PIPE-8580 products of flames_obs_scired should be in binary table
    PIPE-8563 Potential bug with uves_obs_scired
    PIPE-8550 Provide a first implementation that fixes the response computation problem
    PIPE-8545 Strange ref std star catalog spectra
    PIPE-8543 Use a different atmospheric extinction table with more sampling points.
    PIPE-8527 Use X-shooter reference STD star catalogs and merge them in a single one
    PIPE-8260 FLUXCAL_SCIENCE_REDU created if only INSTR_RESPONSE_REDL is in sof
    PIPE-8240 uves_obs_scired: Allow to specify two rebinning steps for RED data
    PIPE-7642 response drops off at bluest reference poinst for 346 setup
    PIPE-6357 wrong variance data product calculation in UVES CPL pipeline

v 5.10.4 (2019-05-04):
  - Public release
  - Updated uves_wkf.oca to fix PIPE-8382
  - fixed PIPE-8395: Incorrect keyword 'EXTNAME' in FITS header
  - fixed PIPE-8247: uves_cal_response: debug=true changes products drastically

v 5.10.0 (2019-04-01):
  - Update to CPL-7.1.1
  Addressed the following actions:
  PIPE-8242: typo in user manual
  PIPE-8241: uves_obs_scired: --reduce.rebin.scale = False - why
  PIPE-8234: uves_obs_scired: online help gives wrong tags for science data
  PIPE-8132: Change UVES Gasgano preference for image display
  PIPE-7812: UVES PARASITIC DARKs classified but no action in OCA rules
  PIPE-7803: UVES pipeline on MacPorts still requiring obsolete llvm
  PIPE-7799: kit missing reflex tutorial
  PIPE-7753: Update the SCRIPTS_DIR path in the Gasgano preferences
  PIPE-5435: Missing fibre spectrum on REDU 580SimCal
  PIPE-6813: Automatic reduction for FLAMES UVES science failed for 520-nm setting

v 5.9.0 (2018-04-01):
  -Updated of DFS for Paranal 2018
  -Updated reflex oca rules to support new esoreflex-2.9.0
  -Fix Reflex fv problems opening product files for inspection